Notice bibliographique (sans auteurs) : | A randomised prospective study comparing the new vacuum extractor policy with forceps delivery. Br J Obstet Gynaecol. 1993 Jun;100(6):524-30. |
Auteur·e(s) : | Johanson RB, Rice C, Doyle M, Arthur J, Anyanwu L, Ibrahim J, Warwick A, Redman CW, O’Brien PM. |
Année de publication : | 1993 |
URL(s) : | |
Résumé (français) : | |
Abstract (English) : | OBJECTIVE: To compare assisted vaginal delivery by forceps with delivery by vacuum extractor, where a new vacuum extractor policy was employed which dictated the cup to be used in specific situations. DESIGN: Multicentre randomised controlled trial. SETTING: Four district general hospitals in the West Midlands. SUBJECTS: Six hundred-seven women requiring assisted vaginal delivery, of whom 296 were allocated to vacuum extractor delivery and 311 to forceps. MAIN OUTCOME MEASURES: Delivery success rate, maternal perineal and vaginal injuries, maternal anaesthetic requirements, neonatal scalp and facial injuries. RESULTS: Of the vacuum extractor group, 85% were delivered by the allocated instrument compared to 90% in the forceps group (odds ratio (OR) 0.64; 95% confidence intervals (CI) 0.4-1.04). However, more women in the vacuum extractor group were delivered vaginally (98%) than in the forceps group (96%). There were significantly fewer women with anal sphincter damage or upper vaginal extensions in the vacuum extractor group (11% vs 17%, OR 0.6; 95% CI, 0.38-0.97). There were significantly fewer women in the vacuum extractor group requiring epidural or spinal anaesthetics (25.4% vs 32.7%, OR 0.69; 95% CI 0.49-0.99) or general anaesthetics (1% vs 4%, OR 0.17; 95% CI 0.04-0.76). Although there were significantly more babies in the vacuum extractor group with cephalhaematomata (9% vs 3%, OR 3.3; 95% CI 1.4-7.4) there were fewer babies in the vacuum extractor group with other facial injuries. There were three babies in the forceps group with unexplained neonatal convulsions. CONCLUSIONS: Assisted vaginal delivery using the new vacuum extractor policy is associated with significantly less maternal trauma than with forceps. Further studies are required to assess neonatal morbidity adequately. |
Sumário (português) : |
|
Resumen (español) : |
|
Remarques : | |
Argument (français) : | |
Argument (English): |
|
Argumento (português): |
|
Argumento (español): |
|
Mots-clés : | ➡ déchirures ; extraction instrumentale ; forceps ; ventouse ; morbidité |
Auteur·e de cette fiche : | Cécile Loup — 20 Apr 2004 |
Discussion (afficher uniquement le français) | ||
---|---|---|
Autre requête experte --- Autre requête simple
Création d'une fiche --- Importation de fiches
Gestion des utilisateurs --- Sauvegarder la base de données --- Contact
Cette base de données créée par l'Alliance francophone pour l'accouchement respecté est gérée
par le Collectif interassociatif autour de la naissance (CIANE, https://ciane.net).
Elle est alimentée par les contributions de bénévoles intéressés par le partage des informations scientifiques.
Si vous approuvez ce projet, vous pouvez nous aider de plusieurs manières :
(1) devenir contributeur sur cette base, si vous avez un peu d'expérience en documentation
(2) ou soutenir financièrement le CIANE (voir ci-dessous)
(3) ou devenir membre d'une association affiliée au CIANE.
➡ Connectez-vous ou créez un compte pour suivre les modifications ou devenir éditrice.
➡ Contactez bibli(arobase)ciane.net pour plus d'informations.
Nos ressources servent principalement à couvrir les frais d’hébergement des sites et bases de données, l’impression de flyers et occasionnellement des frais de transport. Les donateurs particuliers peuvent demander un reçu fiscal du CIANE donnant droit, en France, à une réduction d’impôt égale à 66 % du montant dans la limite de 20% du revenu imposable (voir texte) |