Database - (CIANE) | |
Description of this bibliographical database (CIANE website) |
https://ciane.net/id=697 | ➡ Modify this record |
Bibliographical entry (without author) : | A randomised prospective study comparing the new vacuum extractor policy with forceps delivery. Br J Obstet Gynaecol. 1993 Jun;100(6):524-30. |
Author(s) : | Johanson RB, Rice C, Doyle M, Arthur J, Anyanwu L, Ibrahim J, Warwick A, Redman CW, O’Brien PM. |
Year of publication : | 1993 |
URL(s) : | |
Résumé (français) : |
|
Abstract (English) : | OBJECTIVE: To compare assisted vaginal delivery by forceps with delivery by vacuum extractor, where a new vacuum extractor policy was employed which dictated the cup to be used in specific situations. DESIGN: Multicentre randomised controlled trial. SETTING: Four district general hospitals in the West Midlands. SUBJECTS: Six hundred-seven women requiring assisted vaginal delivery, of whom 296 were allocated to vacuum extractor delivery and 311 to forceps. MAIN OUTCOME MEASURES: Delivery success rate, maternal perineal and vaginal injuries, maternal anaesthetic requirements, neonatal scalp and facial injuries. RESULTS: Of the vacuum extractor group, 85% were delivered by the allocated instrument compared to 90% in the forceps group (odds ratio (OR) 0.64; 95% confidence intervals (CI) 0.4-1.04). However, more women in the vacuum extractor group were delivered vaginally (98%) than in the forceps group (96%). There were significantly fewer women with anal sphincter damage or upper vaginal extensions in the vacuum extractor group (11% vs 17%, OR 0.6; 95% CI, 0.38-0.97). There were significantly fewer women in the vacuum extractor group requiring epidural or spinal anaesthetics (25.4% vs 32.7%, OR 0.69; 95% CI 0.49-0.99) or general anaesthetics (1% vs 4%, OR 0.17; 95% CI 0.04-0.76). Although there were significantly more babies in the vacuum extractor group with cephalhaematomata (9% vs 3%, OR 3.3; 95% CI 1.4-7.4) there were fewer babies in the vacuum extractor group with other facial injuries. There were three babies in the forceps group with unexplained neonatal convulsions. CONCLUSIONS: Assisted vaginal delivery using the new vacuum extractor policy is associated with significantly less maternal trauma than with forceps. Further studies are required to assess neonatal morbidity adequately. |
Sumário (português) : |
|
Resumen (español) : |
|
Comments : | |
Argument (français) : |
|
Argument (English): | |
Argumento (português): |
|
Argumento (español): |
|
Keywords : | ➡ perineal/vaginal tears ; instrumental delivery ; forceps delivery ; vacuum extraction (ventouse) ; morbidity |
Author of this record : | Cécile Loup — 20 Apr 2004 |
Discussion (display only in English) | ||
---|---|---|
New expert query --- New simple query
Creating new record --- Importing records
User management --- Dump database --- Contact
This database created by Alliance francophone pour l'accouchement respecté (AFAR) is managed
by Collectif interassociatif autour de la naissance (CIANE, https://ciane.net).
It is fed by the voluntary contributions of persons interested in the sharing of scientific data.
If you agree with this project, you can support us in several ways:
(1) contributing to this database if you have a minimum training in documentation
(2) or financially supporting CIANE (see below)
(3) or joining any society affiliated with CIANE.
➡ Sign in or create an account to follow changes or become an editor.
➡ Contact bibli(arobase)ciane.net for more information.
Donating to CIANE (click “Faire un don”) will help us to maintain and develop sites and public databases towards the support of parents and caregivers’ informed decisions with respect to childbirth |