Choose your font:
 Arimo
 Merriweather
 Mukta Malar
 Open Sans Condensed
 Rokkitt
 Source Sans Pro
 Login


 English 
 Français 
 Português 
 Español 

[Valid RSS] RSS
bar

Database - (CIANE)

Description of this bibliographical database (CIANE website)
Currently 3111 records
YouTube channel (tutorial)

https://ciane.net/id=2391

Created on : 24 Mar 2010
Modified on : 24 Mar 2010

 Modify this record
Do not follow this link unless you know an editor’s password!


Share: Facebook logo   Tweeter logo   Easy

Bibliographical entry (without author) :

Morbidité materno-fœtale liée à l’extraction instrumentale par spatules de Teissier. Étude comparative à la ventouse obstétricale de type Minicup® Comparing fetal and maternal morbidities between operative deliveries by Teissier’s spatulas and Minicup® vacuum extractor Journal de Gynécologie Obstétrique et Biologie de la Reproduction Volume 38, numéro 8 pages 642-647 (décembre 2009)

Author(s) :

Z. Aouar, R. Ramanah, M. Mangin, F. Leung, B. Mulin 1, L. Courtois, S. Cossa, R. Maillet, D. Riethmuller

Year of publication :

2009

URL(s) :

http://www.em-consulte.com/article/232111
https://doi.org/10.1016/j.jgyn.2009.08.006

Résumé (français)  :

Objectif
Comparer la morbidité materno-fœtale de l’extraction par spatules de Teissier longues à celle de la ventouse obstétricale de type Minicup®.

Matériel et méthodes
Étude rétrospective monocentrique du 1er janvier 2003 au 31 juillet 2008. Durant cette période, toutes les extractions instrumentales réalisées par spatules de Teissier sur singletons en présentation céphalique à terme (≥ 37 semaines d’aménorrhées) ont été recensées. Le groupe témoin a été constitué de chaque extraction par ventouse précédant chaque cas.

Résultats
Nous avons recensé 69 cas d’extraction par spatules de Teissier longues. Les caractéristiques maternelles ne retrouvaient pas de différence significative entre les deux groupes. Deux extractions par spatules se sont compliquées de déchirures périnéales du troisième degré, mais sans différence significative avec le groupe ventouse. Un taux d’épisiotomie de 15,9 % accompagnait les extractions par spatules, contre 11,6 % dans le groupe ventouse (non significatif). La seule donnée significativement différente était la durée d’extraction supérieure dans le groupe ventouse (4,95minutes contre 3,4minutes dans le groupe spatules, p =0,007). La morbidité fœtale était comparable dans les deux groupes.

Conclusion
Au terme de cette étude, aucune différence significative de morbidité materno-fœtale n’a été retrouvée entre le groupe d’extraction par spatules de Teissier et le groupe ventouse. De plus et contrairement à ce que décrit la littérature sur les spatules de Thierry, les spatules de Teissier longues peuvent être utilisées dans le cadre d’une politique restrictive du recours à l’épisiotomie, ce qui va dans le sens des recommandations professionnelles et de la demande des parturientes. Une étude de plus ample envergure devra être réalisée pour confirmer ces données préliminaires.

Abstract (English)  :

Objective
To compare fetal and maternal morbidities between operative deliveries by long Teissier’s spatulas and Minicup® vacuum extractor.

Material and methods
A retrospective study was conducted from January 2003 to July 2008 at the maternity ward, Besançon teaching hospital. Operative deliveries in term cephalic singleton pregnancies performed by Teissier’s spatulas (case group) were compared to previous deliveries by vacuum extractor Minicup® (control group).

Results
During the study period, 69 operative deliveries by Teissier’s spatulas have been performed. No significant difference was found between the two groups in terms of maternal characteristics. Two third-degree perineal tears occurred following delivery by Teissier’s spatulas with no third-degree tear in the vacuum extractor group (p =ns).

The episiotomy rate in the Teissier’s spatulas group was 15,9% compared to 11.6% in the vacuum extractor group (p =ns). Duration of operative delivery was significantly shorter in the Teissier’s spatulas group (3.4min vs 4.95min; p =0.007). Fetal morbidity was identical in the two groups.

Conclusion
This study found no significant difference in terms of fetal and maternal morbidities between operative deliveries by Teissier’s spatulas and vacuum extractor.

Moreover, as opposed to Thierry’s spatulas, the long Tessier spatulas can be adequately used in accordance with pateint’s wish and pratice guidelines recommending a policy of restrictive episiotomy. However, a larger study is needed to confirm these preliminary results.

Sumário (português)  :

Resumen (español)  :

Comments :

Argument (français) :

Argument (English):

Argumento (português):

Argumento (español):

Keywords :

➡ episiotomy ; instrumental delivery ; forceps delivery ; vacuum extraction (ventouse)

Author of this record :

Emmanuelle Phan — 24 Mar 2010

Discussion (display only in English)
 
➡ Only identified users



 I have read the guidelines of discussions and I accept all terms (read guidelines)

barre

New expert query --- New simple query

Creating new record --- Importing records

User management --- Dump database --- Contact

bar

This database created by Alliance francophone pour l'accouchement respecté (AFAR) is managed
by Collectif interassociatif autour de la naissance (CIANE, https://ciane.net).
It is fed by the voluntary contributions of persons interested in the sharing of scientific data.
If you agree with this project, you can support us in several ways:
(1) contributing to this database if you have a minimum training in documentation
(2) or financially supporting CIANE (see below)
(3) or joining any society affiliated with CIANE.
Sign in or create an account to follow changes or become an editor.
Contact bibli(arobase)ciane.net for more information.

Valid CSS! Valid HTML!
Donating to CIANE (click “Faire un don”) will help us to maintain and develop sites and public
databases towards the support of parents and caregivers’ informed decisions with respect to childbirth