Choose your font:
 Arimo
 Merriweather
 Mukta Malar
 Open Sans Condensed
 Rokkitt
 Source Sans Pro
 Login


 English 
 Français 
 Português 
 Español 

[Valid RSS] RSS
bar

Database - (CIANE)

Description of this bibliographical database (CIANE website)
Currently 3111 records
YouTube channel (tutorial)

https://ciane.net/id=825

Created on : 30 Jun 2004
Modified on : 27 Oct 2018

 Modify this record
Do not follow this link unless you know an editor’s password!


Share: Facebook logo   Tweeter logo   Hard

Bibliographical entry (without author) :

Influence of spontaneous and instrumental vaginal delivery on objective measures of pelvic organ support: assessment with the pelvic organ prolapse quantification (POPQ) technique and functional cine magnetic resonance imaging. European Journal of Obstetrics & Gynecology and Reproductive Biology 2004;115(1):32-38.

Author(s) :

Dannecker C, Lienemann A, Fischer T, Anthuber C.

Year of publication :

2004

URL(s) :

httphttps://www.sciencedirect.com/science/article/…
https://doi.org/10.1016/j.ejogrb.2003.09.047

Résumé (français)  :

OBJECTIF : Déterminer l’influence de l’accouchement vaginal spontané et instrumenté sur les mesures objectives du soutien des organes pelviens.

TYPE D’ÉTUDE : Étude prospective dans un hôpital universitaire avec deux groupes d’étude: accouchement spontané par voie vaginale (n = 26) et extraction sous vide (n = 49). Le groupe témoin était constitué de volontaires nullipares en bonne santé (n = 20). Les participants ont subi une évaluation du soutien des organes pelviens en utilisant l’examen de quantification du prolapsus des organes pelviens (POPQ) et en imagerie par résonance magnétique ciné (Cine) postpartum.

RÉSULTATS : Des différences significatives entre les mesures individuelles des composants POPQ ont été notées pour les points Aa et Ba, TVL et GH (libération spontanée versus contrôle) et en outre pour Ap, Bp et D (extraction sous vide versus contrôle). Des différences significatives pour les mesures IRM ont été observées pour la position de la base de la vessie, du col de la vessie, du suffixe postérieur du vagin, de la jonction ano-rectale, du périmètre du hiatus et de la profondeur du rectocèle.

CONCLUSIONS : Des modifications considérables du soutien des organes pelviens après un accouchement vaginal peuvent être démontrées par un système de classification clinique reproductible et fiable (POPQ) et par une imagerie par résonance magnétique fonctionnelle.

Abstract (English)  :

OBJECTIVE: To determine the influence of spontaneous and instrumented vaginal delivery on objective measures of pelvic organ support.

STUDY DESIGN: Prospective study at a university hospital with two study groups: vaginal spontaneous delivery (n=26) and vacuum extraction (n=49). Control group consisted of healthy nulliparous volunteers (n=20). Participants underwent pelvic organ support evaluation by use of the pelvic organ prolapse quantification (POPQ) examination and postpartum functional cine magnetic resonance imaging (MRI).

RESULTS: Significant differences for individual POPQ component measurements were noted for points Aa and Ba, TVL, and GH (spontaneous delivery versus control) and in addition for Ap, Bp, and D (vacuum extraction versus control). Significant differences for MRI measurements were observed for the position of bladder base, bladder neck, posterior fornix of the vagina, anorectal junction, hiatus perimeter and depth of rectocele.

CONCLUSIONS: Considerable changes in pelvic organ support after vaginal delivery can be demonstrated by a reproducible and reliable clinical classification system (POPQ) and by functional cine magnetic resonance imaging.

Sumário (português)  :

Resumen (español)  :

Comments :

Argument (français) :

Des modifications considérables du soutien des organes pelviens après un accouchement vaginal peuvent être démontrées par un système de classification clinique reproductible et fiable (POPQ) et par une imagerie par résonance magnétique fonctionnelle.

Argument (English):

Considerable changes in pelvic organ support after vaginal delivery can be demonstrated by a reproducible and reliable clinical classification system (POPQ) and by functional cine magnetic resonance imaging.

Argumento (português):

Mudanças significativas no suporte de órgãos pélvicos após o parto vaginal podem ser demonstradas por um sistema de classificação clínica reprodutível e confiável (POPQ) e ressonância magnética funcional.

Argumento (español):

Keywords :

➡ evidence-based medicine/midwifery ; public health ; incontinence/prolapsus ; vacuum extraction (ventouse)

Author of this record :

Cécile Loup — 30 Jun 2004
➡ latest update : Bernard Bel — 27 Oct 2018

Discussion (display all languages)
 
➡ Only identified users



 I have read the guidelines of discussions and I accept all terms (read guidelines)

barre

New expert query --- New simple query

Creating new record --- Importing records

User management --- Dump database --- Contact

bar

This database created by Alliance francophone pour l'accouchement respecté (AFAR) is managed
by Collectif interassociatif autour de la naissance (CIANE, https://ciane.net).
It is fed by the voluntary contributions of persons interested in the sharing of scientific data.
If you agree with this project, you can support us in several ways:
(1) contributing to this database if you have a minimum training in documentation
(2) or financially supporting CIANE (see below)
(3) or joining any society affiliated with CIANE.
Sign in or create an account to follow changes or become an editor.
Contact bibli(arobase)ciane.net for more information.

Valid CSS! Valid HTML!
Donating to CIANE (click “Faire un don”) will help us to maintain and develop sites and public
databases towards the support of parents and caregivers’ informed decisions with respect to childbirth