Escolha sua fonte:
 Arimo
 Merriweather
 Mukta Malar
 Open Sans Condensed
 Rokkitt
 Source Sans Pro
 Login


 Português 
 Français 
 English 
 Español 

[Valid RSS] RSS
bar

Banco de dados - (CIANE)

Descrição deste banco de dados documental (Site da CIANE)
Atualmente 3111 fichas
Canal do YouTube (tutorial)

https://ciane.net/id=370

Criado em : 19 Jan 2004
Alterado em : 01 Dec 2007

 Modificar esta ficha
Siga este link somente se você tiver um palavra chave de editor!


Compartilhar: Facebook logo   Tweeter logo   Difícil

Nota bibliográfica (sem autor) :

Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation. American Journal of Obstetrics and Gynecology 2003;189(6):1792-1802.

Autores :

Gonçalves LF, Lee W, Chaiworapongsa T, Espinoza J, Schoen ML, Falkensammer P, Treadwell M, Romero R.

Ano de publicação :

2003

URL(s) :

http://www.sciencedirect.com/science/article/B6W9P…

Résumé (français)  :

Abstract (English)  :

OBJECTIVE : This study was undertaken to describe a new technique for the examination of the fetal heart using four-dimensional ultrasonography with spatiotemporal image correlation (STIC).

STUDY DESIGN :
Volume data sets of the fetal heart were acquired with a new cardiac gating technique (STIC), which uses automated transverse and longitudinal sweeps of the anterior chest wall. These volumes were obtained from 69 fetuses: 35 normal, 16 with congenital anomalies not affecting the cardiovascular system, and 18 with cardiac abnormalities. Dynamic multiplanar slicing and surface rendering of cardiac structures were performed. To illustrate the STIC technique, two representative volumes from a normal fetus were compared with volumes obtained from fetuses with the following congenital heart anomalies: atrioventricular septal defect, tricuspid stenosis, tricuspid atresia, and interrupted inferior vena cava with abnormal venous drainage.

RESULTS :
Volume datasets obtained with a transverse sweep were utilized to demonstrate the cardiac chambers, moderator band, interatrial and interventricular septae, atrioventricular valves, pulmonary veins, and outflow tracts. With the use of a reference dot to navigate the four-chamber view, intracardiac structures could be simultaneously studied in three orthogonal planes. The same volume dataset was used for surface rendering of the atrioventricular valves. The aortic and ductal arches were best visualized when the original plane of acquisition was sagittal. Volumes could be interactively manipulated to simultaneously visualize both outflow tracts, in addition to the aortic and ductal arches. Novel views of specific structures were generated. For example, the location and extent of a ventricular septal defect was imaged in a sagittal view of the interventricular septum. Furthermore, surface-rendered images of the atrioventricular valves were employed to distinguish between normal and pathologic conditions. Representative video clips were posted on the Journal’s Web site to demonstrate the diagnostic capabilities of this new technique.

CONCLUSION :
Dynamic multiplanar slicing and surface rendering of the fetal heart are feasible with STIC technology. One good quality volume dataset, obtained from a transverse sweep, can be used to examine the four-chamber view and the outflow tracts. This novel method may assist in the evaluation of fetal cardiac anatomy.

Sumário (português)  :

Resumen (español)  :

Comentários :

Argument (français) :

Argument (English):

Argumento (português):

Argumento (español):

Palavras-chaves :

➡ despistagem ; ecografia

Autor da esta ficha :

Cécile Loup — 19 Jan 2004

Discussão (exibir apenas português)
 
➡ Reservado para usuários identificados



 Li a carta de discussões e aceito as condições
[Ocultar diretrizes]

➡ Diretrizes de discussão

1) Os comentários são destinados a esclarecer o conteúdo do artigo ou fornecer links para aprofundar o assunto
2) Os comentários são públicos e as opiniões expressas são de responsabilidade dos autores
3) Evite anedotas e histórias pessoais
4) Quaisquer comentários fora do tópico ou que contenham comentários inaceitáveis serão excluídos sem aviso prévio

barre

Efectuar uma nova consulta especialista --- Outro pedido simples

Criação de uma ficha --- Importar registros

Gerenciamento de usuários --- Fazer backup do banco de dados --- Contato

bar

Esta base de dados criada pela Alliance francophone pour l'accouchement respecté (AFAR) é gerida
pela Collectif interassociatif autour de la naissance (CIANE, https://ciane.net).
Ele é alimentado pelas contribuições de voluntários interessados ​​em compartilhar informações científicas.
Se você aprovar este projeto, você pode nos ajudar de várias maneiras:
(1) tornar-se um colaborador com base nisso, se você tem um pouco experiência na literatura científica
(2) ou apoio financeiro CIANE (veja abaixo)
(3) ou tornar-se um membro da outra associação afiliada à CIANE.
Faça login ou crie uma conta para seguir as alterações ou se tornar um editor.
Contato bibli(arobase)ciane.net para mais informações.

Valid CSS! Valid HTML!
Doar para a CIANE (clique em “Faire un don”) nos ajudará a manter e desenvolver sites e bancos de dados
públicos para o apoio das decisões informadas dos pais e cuidadores com relação ao parto